Results for “Beiyi E0192”

1 shown · original source content

EU

EU Safety Gate

1 · European Economic Area

17/01/2014A12/0083/14
EU SAFETY GATE · SOURCE CONTENT

GU10 LED Lamp · Electric shock

Product: LED lamp · Beiyi · E0192

Category: Electrical appliances and equipment · United Kingdom

Hazard: The lens and the cap retaining ring can be easily unscrewed allowing access to live parts. Internal connections are not secondary secured and insulation is not fully completed. The clearance distances on primary and secondary windings are insufficient. The product does not comply with the Low Voltage Directive and the relevant European standard EN 62560.

Official action: Type of economic operator to whom the measure(s) were ordered: Other Category of measure(s): Temporary ban on the supply, offer to supply and display of the product Date of entry into force: 02/10/2013