Energy Display · Electric shock
Product: Energy meter · ELIQ · CPA0500050 (power adapter)
Category: Electrical appliances and equipment · Finland
Hazard: The electrical insulation of the power supply is not adequate. The clearance /creepage distances between the primary and secondary windings of the power supply are too small.The product does not comply with the requirements of the Low Voltage Directive and the relevant European standard EN 60950.
Official action: Type of economic operator to whom the measure(s) were ordered: Other Category of measure(s): Recall of the product from end users Date of entry into force: 27/05/2016Type of economic operator to whom the measure(s) were ordered: Other Category of measure(s): Withdrawal of the product from the market Date of entry into force: 27/05/2016