Flue Logic HE, E-Box and E-Studio · Asphyxiation
Product: Gas fire · GAZCO · Information on models, types and serial numbers is given in the company recall notice.
Category: Gas appliances and components · United Kingdom
Hazard: Aluminium rivets were used instead of steel rivets for the fixings for the draught diverter plate. Failure of the rivets could lead to the draught diverter plate moving out of position which, in combination with the failure of the safety cut off switch, could cause carbon monoxide to enter the room.The product does not comply with the requirements of the Gas Appliances Directive.
Official action: Type of economic operator taking notified measure(s): Manufacturer Category of measure(s): Warning consumers of the risks Date of entry into force: 16/03/2017Type of economic operator taking notified measure(s): Distributor Category of measure(s): Retro fit of adaption plate to prevent baffle plate movement Date of entry into force: 16/03/2017