LED valosarja · Electric shock
Product: Lighting chain · e-ville · Pakkaus / Package: P39437636. Ohjainlaite / Control unit: EK-04
Category: Lighting chains · Finland
Hazard: The accessible wires have only basic insulation and the insulation for the LEDs is inadequate. As a consequence, accessible parts could become live and live parts become accessible, which could result in electric shock. The product does not comply with the requirements of the Low Voltage Directive and the relevant European standards EN 60598 and EN 61347.
Official action: Type of economic operator taking notified measure(s): Manufacturer Category of measure(s): Recall of the product from end users Date of entry into force: 19/10/2018